CZPT CZPT Model : GT 250 MM driven large flow double acting CZPT
CZPT Liquid Stress Booster Injection Pump
CZPT Info for Air driven liquid pumps
CZPT air pushed liquid pumps are ratio gadgets that make use of minimal force compressed
air driving a bigger diameter piston (spot x stress) which is linearly related to a scaled-down
hydraulic piston/plunger. Using this ratio principal, a higher hydraulic force can be generated.
CZPT Pump product numbers replicate the pumps nominal pressure ratio, although the technical data
implies exact ratios. The outlet stall strain is effortless to set by changing the air push pressure
by way of a basic air force regulator.
By multiplying the strain ratio by the available shop
air pressure, the nominal liquid pressure can be calculated.
Exmple ( Pump Model: GH40 liquid pump)
Air generate piston region ( 250mm Ø)
CZPT plunger region ( 40 mm Ø)
Actual ratio = forty:1
1. AIR Generate Section
The air push section is made up of a light fat piston complete with seals operating inside an
aluminum barrel. The diameter of the air piston is 80mm. When compressed air is equipped to
the pump the air pushes the air piston down on a compression stroke
( forces fluid out of the liquid end).
Under the control of pilot pins (poppet valve) triggered at every stop of the stroke
2. CZPT Area (Wetted End)
The hydraulic part of an air driven liquid pump consists of four major pieces, the hydraulic physique,
the piston/plunger, the check out valves and the primary high stress seal. The hydraulic
piston/plunger is directly linked to the air piston and it is housed inside of the hydraulic entire body and
its movement up and down creates the liquid flow into and out of the pump through the check
valves. The examine valves are spring loaded and on the suction stroke the inlet examine valve
opens to the highest making it possible for fluid into the hydraulic entire body and on the compression stroke the
inlet check out valve closes and the discharge check valve opens forcing the pumped fluid into the
approach. The major large stress seal is found within the hydraulic body and the piston/plunger seals
against this for the duration of procedure. There are distinct materials and patterns of higher stress seals
based on the fluid getting pumped and the highest pressures of the pump, nonetheless the
CZPT seals are suitable for each drinking water and hydraulic fluid use.
CZPT air pushed liquid pumps are self-priming, However, large ratio pumps are a lot more difficult to
Prime and might need bleeding. In standard, it is not recommended to use an air- line lubricator.
CZPT air driven liquid pumps cycle automatically as the outlet force boosts the
resistance also increases and the cycle rate decreases until the pump stops immediately
when the output pressure forces are equal. This is referred to as the stall issue.
The pump will restart with a slight drop in the outlet pressure or an increase in the air push
strain. Pump overall performance can be afflicted by a amount of conditions, such as freezing of the
exhaust muffler or pilot valves (which is caused by moisture in air lines), inadequate inlet air-line
dimensions and dirty filers. When functioning the pumps on a steady foundation, we advocate you use
a optimum cycle rate of 50~60 cycles for every moment.
This will both improve services intervals and aid in avoiding ice forming
at the exhaust. An air provide dryer will also aid in decreasing icing up.
To acquire ideal general functionality, it is advised not to lessen the indicated port sizes
and consult We for flow conditions not demonstrated in charts.
Typical apps for high strain pneumatic water testing pump
Crucial functions
One particular model available in 8 ratios
Compatibility with a selection of liquids
Safe pneumatic procedure
Aluminum bodies and wetted components of carbon steel or stainless steel
Rugged,compact,dependable and easy servicing confirmed design and style
Substantial quality seals, extended provider daily life obtainable
No want for air line lubrication
Wide software with big assortment of force ratio
Principal technical data
Typical complex data for air driven chemical injection pump
GT serial Substantial circulation pneumatic chemical injection pump | |||||||||||||||||||||
Air pushed pressure at seven bar At bar pressure ,air intake is around 1.six M3 for each min | |||||||||||||||||||||
Product | Piston/Rod diameter ø(mm) | Displacement for each stroke(mL) | Liquid IN | Liquid OUT | Max presusre Bar at driven pressure eight.3Bar | Liquid outlet (Bar) 1Bar=.1Mpa=one.019Kg/cm² | |||||||||||||||
20 | 40 | 70 | 100 | one hundred fifty | 200 | 300 | 400 | five hundred | 600 | seven-hundred | 900 | 1200 | 1700 | 2350 | |||||||
Movement rate L/Min | |||||||||||||||||||||
GT10 | eighty | 1407.43 | PT3/4″ | PT3/4″ | 83 | 168.89 | 140.74 | 126.sixty seven | 112.59 | ninety eight.fifty two | 84.forty five | ||||||||||
GT25 | 50 | 549.78 | PT3/four” | PT3/4″ | 207 | 65.97 | fifty four.ninety eight | 49.48 | 43.98 | 38.forty eight | 32.ninety nine | 27.forty nine | 21.ninety nine | sixteen.49 | |||||||
GT40 | forty | 351.86 | PT3/4″ | PT3/four” | 332 | 42.22 | 38.7 | 35.19 | 33.43 | 29.ninety one | 26.39 | 21.eleven | seventeen.59 | fourteen.07 | 12.32 | ten.56 | |||||
GT69 | thirty | 197.ninety two | PT3/4″ | NPT1/two” | 572 | 23.seventy five | 22.76 | 21.seventy seven | 19.seventy nine | 17.eighty one | fifteen.83 | thirteen.eighty five | eleven.88 | 9.nine | seven.92 | 6.ninety three | 5.94 | one.ninety eight | |||
GT100 | 25 | 137.44 | NPT1/2″ | NPT1/2″ | 830 | 16.49 | fifteen.eighty one | fifteen.12 | fourteen.forty three | thirteen.74 | twelve.37 | 11 | 9.sixty two | eight.twenty five | six.87 | five.5 | four.81 | 4.twelve | one.37 | ||
GT156 | twenty | 87.ninety six | NPT1/2″ | *HF6 | 1295 | 10.fifty six | 10.12 | 9.68 | 9.24 | eight.8 | 7.92 | 7.04 | six.sixteen | five.28 | 4.4 | 3.fifty two | 3.08 | 2.64 | two.two | 1.seventy six | |
GT190 | 18 | seventy one.25 | NPT3/eight” | *HF6 | 1577 | eight.55 | eight.19 | 8.19 | seven.84 | seven.forty eight | seven.thirteen | 6.forty one | five.seven | four.99 | 4.28 | 3.fifty six | three.21 | 2.eighty five | three.21 | 1.seventy eight | |
GT240 | sixteen | fifty six.three | NPT3/8″ | *HF6 | 2116 | six.76 | six.forty seven | six.forty seven | six.19 | 5.91 | five.sixty three | 5.07 | four.five | 3.ninety four | three.38 | 2.eighty two | two.53 | 2.25 | 2.fourteen | 1.ninety seven | 1.forty one |
Remark one) Maxium outlet force are at an air pushed strain of eight bar or 116 PSI ,for prolonged existence using
of such pump ,we recommend that air driven strain should be not far more than eight Bar
Standard diagram of this sort of air driven liquid pumps
Item Applications
Manufacturing unit corners